LevelManager (LM) is an integrated security system with single outputs (on/off) with Ethernet and RS-485/422 interface. It can be equiped in SMS/GSM/GPRS module. LevelManager can work as main host of
eHouse 1 system and replaces the following devices: ExternalManager, InputExtender, Expanders, RS-232/485 converter and takes over most of the communication functions of a PC.
Features of LevelManager: - complete, integrated and independent security system controlled from outside the protected zone via SMS, e-mail, Ethernet and WiFi
- allows connection of up to 48 alarm detectors (on/off inputs)
- built-in SMS/GSM/GPRS module for alarm notifications with information on detector names, that have been activated
- built-in controller for blinds, marquess, gates with a maximum of 35 (or 27) independent (2 lines control)
- RS-485 interface for cooperation with eHouse 1 system
- Ethernet interface for direct control via local computer network
- GSM/GPRS module for receiving events controlling the system via SMS and sending alarm notifications
- has programmable movement times, break, control impulse of the roller shutter drive, awnings and gates
- relay outputs for direct connection of the horn, warning lamp, monitoring radio-line, early warning signal
- built-in real-time clock for device synchronization
- advanced calendar - scheduler (128 items) to control the eHouse system
- built-in TCP/IP server to control the system with the possibility of simultaneous connection up to 5 clients.
The servers are equal and allow: - receiving events from TCP / IP panels
- sending logs to the monitoring application
- sending device status to TCP graphic panels and visualization
- obtaining a transparent mode between the Ethernet and RS485 links, etc.
- built-in TCP/IP client to control eHouse Ethernet, WiFi, PRO system
- TCP/IP servers and client use dynamic, secure challenge-response authorization, to prevent a break in the system. The algorithm is different for each system installation. Only devices, panels and software controlling eHouse Home Automation from a given installation are able to connect to the system via TCP/IP.
- Management eHouse 1 system and propagate events and data between modules working in this version (replace the PC computer).
- selectable level of logging in to the system in order to detect troubles in case of errors or damages.
- software & hardware Watch Dog Timer (to reset the device in the event of serious error or system hang).
- three groups of SMS reporting events in the security system:
- information about changing zones
- information on activated alarm detectors
- information on alarm deactivation
- programmable times for activating the alarm output (alarm horn), warnings (warning light) and monitoring (launch of the monitoring radio-line), and early warning outputs
- 21 individually defined security zones
- 4-level mask individually defined for each alarm sensor independently in each zone when the detector is activated:
- activation of the alarm horn (A)
- switching on the warning light (W)
- activation of monitoring (M)
- launch of a specific system event (E)
- built-in 16 channel Analog/Digital Converter for measuring external sensors: e.g. temperature, lighting, wind strength, humidity, Sabotage of the alarm detectors. Exceeding the upper or lower threshold for each channel, enables automatic activation of a system event connected to it or switching on and off the output (in direct mode)
- has individually defined ADC threshold settings settings (max 12)
- has individually defined security programs (max 24), Simultaneous setting of all blinds, marquess, gates and security zone